Re: About Fiber optic gyroscope



praveen wrote:
Hello,
I have a doubt regarding fiber optic gyroscope

Relationship between the driving reference voltage and modulation
index.For example if i want a modulation index of 1.8, how much is the
reference voltage to be applied to PZT.

This depends on everything--the number of turns, the piezo-optic coefficient of the fibre, the wavelength, the size and sensitivity of the piezo. The simplest method is to look at the gyro output on a spectrum analyzer, then increase the AC drive to the PZT until the carrier disappears. That corresponds to a modulation index of 2.40(the first null of the Bessel function J0). Further calibration is then trivial.


Cheers,

Phil Hobbs