Efficiency of a tank circuit or a Pi-tank circuit is given by - Efficiency = Qi / ( Qi + QL ) * 100 percent, where Qi is the intrinsic Q of the coil and QL is the loaded Q of the tank circuit. PROGRAMS AVAILABLE . The following calculate L and C values for given load values and/or tube operating voltages. Pi_L_NET and Pi_TANK also calculate harmonic suppression. TRIODE1 and TETRODE1 compute grid drive, tank circuit conditions and efficiency for Class A, B & C operating conditions and angles. Download progs in a few seconds from website below and run immediately. ........................................................... Regards from Reg, G4FGQ For Free Radio Design Software go to http://www.btinternet.com/~g4fgq.regp ........................................................... "arie" <[EMAIL PROTECTED]> wrote in message news:[EMAIL PROTECTED] > Maybe not quite appropriate for this news-group.. > > Does anybody know a pointer to a program or the methods > of calculations so I can determine the losses occuring > in a PI-filter output for a high-power tube amplifiers. > > I can calculate the required C1, L and C2 values given a > certain anode voltage and current and a certain output > impedance for a loaded Q of 10, 12 or other values, but > what about losses depending on selected loaded-Q values > related to harmonics suppression... > > Thanks in advance, > Arie.