"PravinPawar" <[EMAIL PROTECTED]> wrote in message news:[EMAIL PROTECTED] > Hello, > I am interfacing IDT with 8051 controller on both sides. > The left sides only writes while the right side only reads the data. > > I have made the following wiring > OE_ -- manually toggled by 8051 port bit > r/w_ -- connected to wr_ of 8051 > ce_ -- connected to rd_ of 8051 > busy_ -- connected to Vcc > INT_ -- connected to Vcc > > I get problem when i read the data. i am not reading the same location > at the same time. Instead i first write all the locations from > 0000h - 03ffh .By that time the reading controller is in a delay loop > I am able to read first 60 locations ,however the upper locations give > wrong value .i output the vaues on hyperterminal. > If i read the individual upper locations ,i can read it,so it is > probably not a write problem > Now if i refresh the values ,that is if i re-write the locations again > after a certain delay ,the values outputted are correct. > > What can be the possible problem ,is it a timming problem?? > My RD_ pulse is 250nsec and CE_ pulse is 3 Microseconds. > > Please help me . > > Thanks, > Pravin Leave busy and INT unconnected, tie CE_ to port bit of 8051 and OE_ to rd_ of 8051... regards